ما هي بطاريات رف الخادم?

ما هي بطاريات رف الخادم?
If you’ve been researching modern energy storage, خاصة بالنسبة للطاقة الشمسية أو النسخ الاحتياطي, you’ve likely come across the term "server rack battery." What exactly are they, and why have they become a professional standard for building reliable and scalable energy systems?

A server rack battery is a high-performance lithium battery, typically using the safe and long-lasting 48V LFP (الفوسفات الحديد الليثيوم) كيمياء, built in a standardized 19-inch wide format. This design allows the battery modules to be neatly and securely installed ("racked") into a server cabinet. They are the modular building blocks of a space-efficient, منظم, and easily expandable Battery Energy Storage System (بيس).

An image of several sleek, 19-inch server rack battery modules being installed into a professional cabinet, perhaps next to a hybrid inverter.
A Professional Server Rack Battery System

في GYCX Solar, ملكنا 48بطارية مثبتة على حامل على شكل v solutions are at the core of the advanced energy systems we design. They provide our customers in South Korea and beyond with a powerful, مرن, and future-proof foundation for their energy independence. Let’s answer some of the most common questions about building a system with these batteries.

How to connect 4 batteries to get 48V?

A common way to build a 48V battery bank in the past was to use smaller, more common batteries. How is this done, and how does it compare to using a modern 48V rack battery module?

To create a 48V system from four individual batteries, you must use four identical 12V batteries and connect them electrically في سلسلة. This means wiring them in a chain: الإيجابية (+) terminal of the first battery connects to the negative (-) of the second, الإيجابية (+) of the second connects to the negative (-) من الثالث, وهكذا. The total voltage across the remaining open terminals will be 48V.

A clear and simple wiring diagram showing four 12V batteries connected in a chain (series), with the final output labeled as
Connecting Four 12V Batteries in Series for 48V

الغوص أعمق: Series Wiring and The Modern Solution

يتطلب توصيل البطاريات في السلسلة اهتمامًا دقيقًا بالتفاصيل:

  • The "Identical" قاعدة: This is the most critical part. When connecting in series, all four 12V batteries must be identical in chemistry (على سبيل المثال, all LFP or all AGM), amp-hour (آه) سعة, ماركة, و, ideally, age and manufacturing batch. Using mismatched batteries will cause severe imbalances, leading to poor performance, premature failure of the weaker batteries, and potential safety hazards.
  • The Wiring Path: You create a single path for the current to flow through all batteries. The final 48V output is taken from the main positive terminal of the first battery in the chain and the main negative terminal of the last battery.
  • The Modern Advantage: This is where a modern 48بطارية مثبتة على حامل على شكل v module shows its value. A single one of our modules is already a pre-engineered 48V unit.
    • بساطة: You don’t need to worry about complex series wiring or the risk of mismatched cells.
    • أمان: Each 48V module contains its own advanced Battery Management System (خدمات إدارة المباني) that perfectly balances all the internal cells, a task that is much harder in a DIY series string of 12V batteries.
    • قابلية التوسع: To increase your energy capacity, you simply add another 48V module in parallel, which is a much safer and simpler connection.

While you يستطيع make a 48V bank from four 12V batteries, using purpose-built 48V modules is the safer, simpler, and more professional approach.

How long will a 48 volt 100Ah battery last?

A 48V 100Ah battery is a very popular size for residential solar storage. It’s a substantial amount of energy, but how long can it actually power your home? The answer depends entirely on your electricity consumption.

أ 48بطارية V 100AH stores 4,800 واط ساعة (هل) أو 4.8 كيلووات ساعة (كيلووات ساعة) من الطاقة. How long it will last is calculated by dividing this total energy by your electrical load (في واتس). على سبيل المثال, it could power a continuous 480-watt load for about 10 ساعات, or a lighter 200-watt load for about 24 ساعات.

An infographic showing a 4.8kWh (48V 100Ah) battery with lines pointing to different household appliances and their corresponding runtimes.
Runtime Examples for a 48V 100Ah Battery

الغوص أعمق: Calculating Your Runtime

Let’s walk through the simple math:
خطوة 1: Find the Total Energy in Watt-hours (هل)

  • صيغة: Energy (Wh) = Voltage (V) x Capacity (Ah)
  • حساب: 48V x 100Ah = 4,800 Wh (أو 4.8 كيلووات ساعة)

خطوة 2: Calculate Runtime Based on Your Load

  • صيغة: Runtime (Hours) = Total Energy (Wh) / Load (Watts)

Example Scenarios for a Korean Household:

  • Essential Loads (تقريبا. 300دبليو): Let’s say during an outage, you’re running your high-efficiency refrigerator, بعض مصابيح LED, جهاز توجيه الإنترنت الخاص بك, and charging your phones.
    • 4,800 Wh / 300 W = 16 hours
  • Moderate Loads (تقريبا. 800دبليو): You add a TV and a desktop computer to the essentials.
    • 4,800 Wh / 800 W = 6 hours
  • Heavy Load (تقريبا. 2,000دبليو): You decide to run a portable air conditioner or a high-power appliance.
    • 4,800 Wh / 2,000 W = 2.4 hours

This is why our Gycx Solar 48بطارية مثبتة على حامل على شكل v systems are modular. A 100Ah (4.8كيلووات ساعة) module is a great starting point, but if you need longer runtime, we can easily add a second or third module in parallel to double or triple your capacity.

How many solar panels do you need for a 48V battery?

You have your 48بطارية V. نظام; now you need to charge it with solar. How do you size your solar array to ensure your batteries are charged effectively each day?

The number of solar panels needed depends on your battery’s capacity, your location’s climate, and the wattage of the panels. لإعادة شحن أ 48في 100ah (4.8 كيلووات ساعة) بطارية daily in a climate like South Korea’s, with its distinct seasons, you would generally need a solar array of approximately 1.5 كيلوواط ل 2.5 كيلوواط. This translates to about 4 ل 6 حديث, high-efficiency 400W solar panels.

An image of 5 solar panels on a roof, with an arrow showing energy flow to a 48V rack mount battery system.
Sizing a Solar Array for a 48V Battery

الغوص أعمق: Sizing for a Four-Season Climate

Here’s how we approach sizing a solar array at Gycx Solar:

  1. Energy to Replenish: We need to put back the energy you use daily. ل 4.8 kWh battery using 90% من قدرتها, هذا عن ذلك 4.3 كيلووات ساعة.
  2. ساعات شمس الذروة (PSH): This is the key variable. In South Korea, this changes with the seasons. You might get 4.5-5 PSH in the summer, لكن فقط 2.5-3 PSH in the winter. We often size the array based on a year-round average or spring/autumn value (على سبيل المثال, 3.5 - 4 PSH) to ensure adequate charging for most of the year.
  3. خسائر النظام: We account for energy lost from panel heat, الأسلاك, وكفاءة وحدة تحكم العاكس/الشحن (typically a 15-25% loss factor).
  4. الحساب:
    • الطاقة الشمسية المطلوبة (كيلوواط) = الطاقة اليومية اللازمة (كيلووات ساعة) / (عامل الكفاءة الساعات الذروة X)
    • مثال (based on a conservative 3.5 PSH): 4.3 kWh / (3.5 hours x 0.80 efficiency) = 1.54 kW (1540 Watts)
    • This would mean 1540W / 400W per panel ≈ 4 panels. To be safe and ensure good charging even on less-than-perfect days, we might recommend 5 أو 6 لوحات.

قصة GYCX الشمسية: "A client in Seoul was concerned about winter charging for their 48V battery system. We designed their array based on the lower winter sun-hour data, ensuring that even on a clear winter day, their batteries would receive a meaningful charge. It’s this kind of climate-specific planning that makes a system reliable year-round."

Can I use 12V solar panels on a 48V system?

You might have access to some standard 12V solar panels and want to use them to charge your new, more efficient 48V battery bank. Is this possible, or are they incompatible?

نعم, you can use 12V solar panels on a 48V system, but only with the right configuration. أنت must wire the 12V panels in series to increase their combined voltage to a level high enough to charge a 48V battery. بالإضافة إلى ذلك, أنت must use a high-quality MPPT (الحد الأقصى لتتبع نقطة الطاقة) وحدة تحكم شحن الطاقة الشمسية, which can efficiently manage the voltage difference between the panels and the battery.

A wiring diagram showing four 12V solar panels connected in series to an MPPT charge controller, which then connects to a 48V battery bank.
Using 12V Panels on a 48V System Correctly

الغوص أعمق: The Keys to Compatibility

Here’s what’s required to make this work:

  1. Series Connection of Panels: To charge a 48V battery, your solar array needs to produce a significantly higher voltage (typically 60V or more). A single "12V" panel usually has a max power voltage (VMP) of around 18V.
    • لذلك, you need to connect at least four identical 12V panels in series (positive to negative) to achieve a suitable system voltage (4 panels x ~18Vmp = ~72V).
  2. An MPPT Charge Controller is Essential:
    • A cheap PWM (تعديل عرض النبض) controller cannot be used. It requires the panel voltage to be very close to the battery voltage.
    • و تحكم MPPT is a sophisticated DC-to-DC converter. It can take the high voltage from your series-wired panels (على سبيل المثال, 72الخامس) and efficiently "step it down" to the correct charging voltage for your 48V battery, capturing the maximum amount of power from your panels in the process.
  3. The Professional Approach: While using 12V panels is technically possible, modern system designs for 48V batteries usually use higher-voltage panels from the start (على سبيل المثال, "24V" panels or standard 60/72-cell residential panels with a Vmp of 30-40V). Wiring just two of these in series is simpler and often more efficient.

This highlights the importance of system design. في GYCX Solar, we ensure every component, from the solar panels to the charge controller and the 48بطارية مثبتة على حامل على شكل v, is perfectly matched for optimal safety, أداء, والكفاءة.


A server rack battery is a cornerstone of modern, scalable energy storage. Understanding how to configure, تكلفة, and size a system around a 48V standard1 is key to unlocking its benefits. By using purpose-built 48V modules, you simplify installation and enhance safety, creating a robust foundation for your استقلال الطاقة2.

If you have questions about designing your own 48V energy system or want to learn more about our professional rack mount battery solutions, فريق الخبراء لدينا في GYCX Solar جاهز للمساعدة. اتصل بنا للحصول على استشارة!



  1. Exploring this link will deepen your understanding of the 48V standard’s role in energy storage, enhancing your system’s efficiency.

  2. This resource will provide insights into achieving energy independence, crucial for sustainable living and reducing reliance on traditional power sources.

اترك رد

لن يتم نشر عنوان بريدك الإلكتروني. تم وضع علامة على الحقول المطلوبة *